Laminar Air Flow Horizontal

Laminar Air Flow Horizontal

MODEL: ASE-LAFH-27

UNIQUE FEATURES & BENEFITS

HEPA filtration unit provides Class 100 air quality
Optional UV lamp to sterilize work zone
Low noise level
High airflow capacity
Meet US Federal Standard 209 B (BS 5295)
Stainless steel work table
Made from branded parts (blower etc.)
Easy to change filters

PRODUCT DESCRIPTION

What is Laminar Air Flow?

A laminar air flow workstation is a closed cabinet fitted with HEPA filtered air flow system. Here, laminar means unidirectional constant flow of air with almost no or minimal turbulence. The air flow velocity remains between 0.3 m/s to 0.5 m/s. The purpose of using such workstations in laboratory is to create particle and bacteria free working environment to carry out specialized work. As these units discharge air towards user, they provide no personal protection but product protection from room contaminants. LAF is short form of laminar air flow.

Laminar Air Flow Applications

Laminar air flow systems are used in various applications such as life science research, mushroom cultivation, microbiology, IVF, IUI and histopathology / pathology lab, plant tissue and cell culture and pharmaceutical and electronics industry and many more.

Types of Laminar Air Flow

There are two different types of laminar air flow cabinets are constructed; horizontal and vertical. The difference between vertical and horizontal laminar flow hoods is direction of air flow and placement of HEPA filter. These cabinets are made with either horizontal or vertical air flow systems and have two stages filtration. It is the type of application which decides which is most suitable to use.

Vertical vs Horizontal Laminar Flow

Vertical Laminar Air flow

It is the most used type of laminar air flow. In vertical flow cabinet, room air is entered in working area through HEPA filter fitted on top of the cabinet. Thus, air flows downward (vertically) towards work surface and leaves the cabinet sweeping out particles and bacteria.

Horizontal Laminar Air Flow

In horizontal air flow cabinet, room air is entered in working area through HEPA filter fitted on the back side of the cabinet. Filtered air flows horizontally towards the user creating sterile working environment.

TECHNICAL DESCRIPTION

Parts of Laminar Air Flow Chamber 

Blower: Blower assembly draws room air through pre filter and throws towards HEPA filter

Pre Filter: It is primary air filter which filters room air initially and forward towards HEPA filter. Usually, pre filter keeps out particles 5 microns or higher.

HEPA Filter: This is final filter. Air filtered through pre filter is forwarded towards HEPA filter. HEPA filter offers 99.99% efficiency for 0.3 micron particulates.

Pressure gauge: Magnehelic gauge is used to monitor differential pressure across HEP filter with respect to ambient

Work bench: It is made of stainless steel. Samples / products are put on it for work.

Sash: Sash is sliding front door. User can slide it manually and adjust the opening height as needed.

Light: Light is fitted to provide proper illumination under the working area.

Service fixtures: Main chamber is fitted with electrical socket, air and gas cock.

Germicidal UV lamp: UV lamp is an added option which is used to sterilize working area prior use. It is advised no contact to made in chamber during this time.

We are ISO and CE certified laminar air flow manufacturers and suppliers in India. Our company designs both types of horizontal and vertical laminar flow benches for laboratory uses that meet US Federal Standard 209 B (BS 5295) standards. These units are ruggedly constructed for years of worry free operation and made with stainless steel sheet (304 / 316) or powder coated mild steel or GI sheets.

Air Filtration

The efficiency of a Laminar Air Flow workstation depends upon the quality of pre filters and HEPA filters. In our LAF, the Air filtration system is created to work efficiently even in critical environment. Pre filter that we use are box type pleated having efficiency 95% down to 5 micron and made of HDPE + Non-woven + HDPE mesh media and fitted in aluminum case. The HEPA filters are of high quality having efficiency 99.99 % down to 0.3 micron and fitted in aluminum anodized case. The blower assembly has ¼ HP; 1400 RPM branded motor and has aluminum anodized impellers.

Work Area

The working area is carefully designed for comfortable working and easy cleaning. The workbench is made of stainless steel. Standard fittings are air / gas cock and electrical outlet. For illumination, we use fluorescent lamps. Front side of working area is covered by manual sliding door (sash), which is made of transparent acrylic plastic.

There are some optional features that can be added if required by customer. LCD display for air velocity, time and lamp on/off status are displayed on it. Germicidal UV lamp, extra electrical socket and magnehelic gauge are also fitted if required.

If you want to know about laminar air flow price, customization, installation and validation etc. please email us your detailed query. Our sales personnel will contact you with everything you need.

TECHNICAL SPECIFICATIONS

ParticularDescription
Air flow directionHorizontal
Air cleanlinessClass 100
ConstructionStainless Steel / Powder coated MS / GI sheet
Work Table304 Stainless Steel (Optional 316 grade)
Air flow directionHorizontal
Sash (front door)Manual sliding type (Acrylic transparent)
Side panelsAcrylic / polycarbonate / SS
Air velocity0.45 m/s to 0.65 m/s
BlowerHigh efficient centrifugal type with lifetime lubricated bearings
Illumination1 or 2 LED Light
Noise level65 ±5 db
Power supply220 volts / 50 Hz
Pre-Filter85% efficiency for particles >0.5 μm (Washable)
HEPA filter99.99% efficiency for particles >0.3 μm (0.3 Microns)
Particle CountBetter than US Fed Std 209B Class10 and VDI 2083 Class 3
WheelsUnit mounted on Castor wheels for easy movability
Standard fittings
  • Air / gas cock
  • Mains on/off switch
  • Light on/off switch
  • UV Light on/off switch
  • Blower on/off switch
Optional
  • Motorized sliding door
  • LCD display for velocity, time & lamp on/off
  • UV Germicidal lamp
  • UV Hour meter
  • Magnehelic gauge
  • Extra power outlet switch
  • Foot rest
  • Leveling lugs for stand
  • DOP HEPA filter testing

LAMINAR AIR FLOW HORIZONTAL TYPE MODEL & STANDARD DIMENSIONS / SIZES

ModelDimensions (ft)Dimensions (mm)HEPA Filter SizeNo. of Pre Filters
ASE-LAFH-27-222 x 2 x 2610 x 610 x 6102ft x 2ft x 6inch (1 No.)1
ASE-LAFH-27-323 x 2 x 2915 x 610 x 6103ft x 2ft x 6inch (1 No.)2
ASE-LAFH-27-424 x 2 x 21220 x 610 x 6104ft x 2ft x 6inch (1 No.)2
ASE-LAFH-27-626 x 2 x 21828 x 610 x 6103ft x 2ft x 6inch (2 Nos.)3
ASE-LAFH-27-828 x 2 x 22438 x 610 x 6104ft x 2ft x 6inch (2 Nos.)4