Vacuum Stability Test Apparatus
Vacuum Stability Test Apparatus
Model: ASE-VST-81
UNIQUE FEATURES
Max working temperature: 160°C
Digital Micro-processor based Temperature Controller
Excellent temperature accuracy & uniformity
Imported heating elements
Rugged construction for long run
Fitted with safety devices
Customization as per user requirement
Description
Vacuum stability test is frequently used for determination of chemical stability and compatibility of energetic materials and for quality tests of energetic ingredients. The test is able to discover with high sensitivity, precision and reproducibility chemical instability of energetic materials due to presence of destabilizing impurities, incompatibility with surrounding materials or ageing. Vacuum stability test finds its wide application in qualification, surveillance, manufacture, quality control and R&D of a whole range of energetic materials.
Vacuum stability tester is an apparatus for determination of chemical stability of energetic materials by vacuum stability test. The apparatus uses electronic pressure transducers for measuring the volume of gas evolved on heating multiple samples in evacuated glass test tubes in a heating block maintained at a constant specified temperature for a specified period of time.
We are ISO and CE certified Vacuum Stability Test Apparatus manufacturers and suppliers in India. Each unit is made with rugged construction and equipped with easy to use controller system and safety devices.
If you want to buy any standard or customized model or know Vacuum Stability Test Apparatus price, please email us your query. Our factory is located in Mumbai and we supply Navi Mumbai, Thane, Palghar, Nagpur, Karnataka, Bengaluru, Goa and throughout India.
TECHNICAL SPECIFICATIONS
| Particulars | Description |
|---|---|
| Temperature Range | 35°C to 160°C |
| Temperature accuracy | ±0.1℃ |
| Hole diameter | 19 mm |
| Hole depth | 160 mm |
| Typical sample weight | 5 grams |
| Pressure transducer range | 0 to 100 kPa, accuracy: 0.25 % |
| Barometric pressure transducer range | 80 to 120 kPa, accuracy: 0.25 % |
| Test tube volume | 25 ± 2 ml |
| Sampling rate | 10 s-1 |
| Sensor | Class A Type PT-100 |
| Heating chamber MOC | Special Type heating block |
| Exterior MOC | Powder coated steel |
| Temperature controller | Digital Micro-processor based PID Temperature Controller |
| Safety Controller | For Over temperature Cutoff protection and Alarm and alert systems |
| Safety Features | Over Pressure Cutoff & Alarm Temperature Failure alarm System Heater Failure Trip & Alarm |
| Power supply | 230 Volts A.C 50 Hz Single Phase |
| Compliance | Explosives testing standards: STANAG 4556, 4147, 4022/4, 4023, 4230, 4284, 4566, MIL-STD-650, STANAG 4178 and AOP-48 Electrical safety: CE |
| Accessories |
|
| Optional |
|
Vacuum Stability Test Apparatus Model & Standard Size
| Model | Number Of Sample | Power |
|---|---|---|
| ASE-VST-81-6 | 6 | 230 Volts |
| ASE-VST-81-8 | 8 | 230 Volts |
| ASE-VST-81-12 | 12 | 230 Volts |
| ASE-VST-81-16 | 16 | 230 Volts |
| ASE-VST-81-18 | 18 | 230 Volts |
OUR COMPLETED PROJECTS